Skip to main content

Implants

E2 - Implants Estradiol

Purchase by Order form

I order

E2 - Implants Estradiol


  • Mouse

  • Rat

Belma implants consist of a polymer reservoir surrounded by a hormone diffusion-controlling membrane. They are designed to release daily doses of a hormone to produce physiological or pharmacological plasma concentrations in mice and rats.

Two oestradiol implants have been developed. The first one makes it possible to achieve pre-ovulatory plasma concentrations and is used mainly in hormone-dependent cancer animal models to support tumour cell growth. The second one (E2 Light) makes it possible to deliver pro-oestrous doses and is designed for gynaecological models (e.g., endometriosis).


Tableau 1 : Plasma concentrations, normal values

  Rat  Mouse
E2 (pg/ml) 2,4 – 145,4 2,4 – 145,4
P4 (ng/ml) 1,2 – 18,4 1,2 – 18,4
T (ng/ml) 0,66 – 5,4 1,7 – 14,4

Tableau 2 : Plasma concentrations, values with Belma implants

  Rat  Mouse
Belma E2 (pg/ml) 52 - 108 41,2 - 105,6
Belma E2L (pg/ml)   35,2 - 72,0
Belma P4 (ng/ml) 5,3 – 11,2 3,0 - 5,9
Belma T (ng/ml) 0,9 - 3,7 2,9 - 7,5

Our offer :

Animal Reference Release time
Souris   E2-M/30 30 days
E2-M/60 60 days
E2-M/90 90 days
Rat   E2-R/30 30 days
E2-R/60 60 days
E2-R/90 90 days

Advantageous terms :

  • A 5% discount on orders of more than 100 units.
  • A special discount on orders of more than 500 units: contact us.

Read more …E2 - Implants Estradiol

E2 Light - Implants Estradiol

E2 Light - Implants Estradiol


Mouse Light

Belma implants consist of a polymer reservoir surrounded by a hormone diffusion-controlling membrane. They are designed to release daily doses of a hormone to produce physiological or pharmacological plasma concentrations in mice and rats.

Two oestradiol implants have been developed. The first one makes it possible to achieve pre-ovulatory plasma concentrations and is used mainly in hormone-dependent cancer animal models to support tumour cell growth. The second one (E2 Light) makes it possible to deliver pro-oestrous doses and is designed for gynaecological models (e.g., endometriosis).


Tableau 1 : Plasma concentrations, normal values

  Rat  Mouse
E2 (pg/ml) 2,4 – 145,4 2,4 – 145,4
P4 (ng/ml) 1,2 – 18,4 1,2 – 18,4
T (ng/ml) 0,66 – 5,4 1,7 – 14,4

Tableau 2 : Plasma concentrations, values with Belma implants

  Rat  Mouse
Belma E2 (pg/ml) 52 - 108 41,2 - 105,6
Belma E2L (pg/ml)   35,2 - 72,0
Belma P4 (ng/ml) 5,3 – 11,2 3,0 - 5,9
Belma T (ng/ml) 0,9 - 3,7 2,9 - 7,5

Our offer :

Animal Reference Release time
Mouse E2L-M/30 30 days
E2L-M/60 60 days
E2L-M/90 90 days

Advantageous terms :

  • A 5% discount on orders of more than 100 units.
  • A special discount on orders of more than 500 units: contact us.

Read more …E2 Light - Implants Estradiol

P4 - Implants Progesterone


  • Mouse

  • Rat

Belma implants consist of a polymer reservoir surrounded by a hormone diffusion-controlling membrane. They are designed to release daily doses of a hormone to produce physiological or pharmacological plasma concentrations in mice and rats.


Tableau 1 : Plasma concentrations, normal values

  Rat  Mouse
E2 (pg/ml) 2,4 – 145,4 2,4 – 145,4
P4 (ng/ml) 1,2 – 18,4 1,2 – 18,4
T (ng/ml) 0,66 – 5,4 1,7 – 14,4

Tableau 2 : Concentrations plasmatiques, valeurs mesurées avec les implants Belma

  Rat  Mouse
Belma E2 (pg/ml) 52 - 108 41,2 - 105,6
Belma E2L (pg/ml)   35,2 - 72,0
Belma P4 (ng/ml) 5,3 – 11,2 3,0 - 5,9
Belma T (ng/ml) 0,9 - 3,7 2,9 - 7,5

Our offer :

Animal Reference Release time
Mouse P4-M/30 30 days
  P4-M/60 60 days
  P4-M/90 90 days
Rat P4-R/30 30 jours
  P4-R/60 60 jours
  P4-R/90 90 jours

Advantageous terms :

  • A 5% discount on orders of more than 100 units.
  • A special discount on orders of more than 500 units: contact us.

Read more …P4 - Implants Progesterone

T - Implants Testosterone


  • Mouse

  • Rat

Belma implants consist of a polymer reservoir surrounded by a hormone diffusion-controlling membrane. They are designed to release daily doses of a hormone to produce physiological or pharmacological plasma concentrations in mice and rats.


Tableau 1 : Plasma concentrations, normal values

  Rat  Mouse
E2 (pg/ml) 2,4 – 145,4 2,4 – 145,4
P4 (ng/ml) 1,2 – 18,4 1,2 – 18,4
T (ng/ml) 0,66 – 5,4 1,7 – 14,4

Tableau 2 : Plasma concentrations, values with Belma implants

  Rat  Mouse
Belma E2 (pg/ml) 52 - 108 41,2 - 105,6
Belma E2L (pg/ml)   35,2 - 72,0
Belma P4 (ng/ml) 5,3 – 11,2 3,0 - 5,9
Belma T (ng/ml) 0,9 - 3,7 2,9 - 7,5

Our offer :

Animal Reference Release time
Mouse  T-M/30 30 days
T-M/60 60 days
Rat T-R/30 30 days
T-R/60 60 days

Advantageous terms :

  • A 5% discount on orders of more than 100 units
  • A special discount on orders of more than 500 units: contact us.

Read more …T - Implants Testosterone

DHT - Implants dihydrotestosterone


Mouse

Belma implants consist of a polymer reservoir surrounded by a hormone diffusion-controlling membrane. They are designed to release daily doses of a hormone to produce physiological or pharmacological plasma concentrations in mice and rats.


Our offer :

Animal Reference Release time
Mouse DHT-M/30 30 days
DHT-M/60 60 days
DHT-M/90 90 days

Advantageous terms :

  • A 5% discount on orders of more than 100 units.
  • A special discount on orders of more than 500 units: contact us.

Read more …DHT - Implants dihydrotestosterone

Belma Technologies Copyright © 2015 - 2024 | Avenue de l’Hopital, 11 - 4000 Liège (Belgique) | Création de site : Zzam.be